Cissell DX4 CONTROLLER Instrukcja Użytkownika Strona 3

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 18
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 2
Error Codes
FB08-15 Page 3 of 18
NOTE: * To clear the not 3 error code: coin or vended machines - go to program D and press ECO button
(E). OPL models - Press the ECO button (E) and SELECT button (P) simultaniously. The letter “d” will
appear on the right side, press the ECO button (E) once again. For additional information refer to
instruction manual 249/00368/10.
Table 2
Group 2
Error Code Probable Cause Possible Corrective Actions
E7 (safety level) Water did not drain sufficiently.
Check the drain pump
Check water level switch
Eb (tilt switch) Tilt switch is blocked.
Check for defective tilt switch
Verify wiring at tilt switch is
not disconnected
not 1 (MOT no current) No current supplied to the motor.
Verify flatcable is connected
Check that the cycle contact
MICRO 9 closes
Replace 16 amp fuse
Tighten motor plug
Replace motor print board
not 2 (tach pulse) Motor print board is not receiving
tach pulse from MICRO 9 control.
Check wiring
Replace tac generator
Check contacts A, B, C or D of
MICRO 9 control
Przeglądanie stron 2
1 2 3 4 5 6 7 8 ... 17 18

Komentarze do niniejszej Instrukcji

Brak uwag