63
DX SERIES
TEMPERATURE CONTROLLER
TEMPERATURECONTROLLER
3
(1)
Set-value
(SV)
setting
procedure
Thefollowingareexamplesofsettingtheset-
value(SV)to70℃.(PV:25℃)
((22))EEaacchhppaarraammeetteerr((ootthheerrtthhaannSSVV))sseettttiinnggpprroocceedduurree
Thisparametersettingexampleshowsthatthe
proportional band(P)issetto20℃.
✽ Ifthesettingends,pressingthekeycontinuouslyfor5
sec,againreturnsthecontrollertothePV/SVdisplaymode.
In addition, if no key operation is performed for 1 minute,
the controller is set to the PV/SV display mode
automatically.
①
PressthekeytoentertheSV
setting mode. The last digit of
the set-value(SV) display unit
starts to flicker. The digit which
flickersissettable.
③
Pressthekeytoset“7”.
Pressing thekey digit goes up
and pressing thekey digit comes
down.
·Settingrange:Withininputrange.
Whenmines(-)signisset,
Example:
When 70 is changed to -70, shift
the digit flickering to the two
digits,thenpressthekeytofor
thedigitcomingdownindueorder
of1→0→-1.
②
Pressthekeytoshift thedigit
which flickers up to the two
digits. The digit which flickers
shiftsasfollowseverytimethe
keyispressed:
④
After finishing the setting, press
the key. All of the set-value
digits stop flickering and as a
result, the controller returns to
thePV/SVdisplaymode.
⑤
Pressing thekey after the
setting ends shifts to the next
parameter.Repeattheprocedures
as shown from ② to⑤ to shift
eachparameterinturn.
④
Pressthekeytoset“2”.
Pressingthekey,thedigit
goesup,andpressingthe
key,thedigitcomesdown.
③
Press the key to shift the
digitwhichflickersuptothetwo
digits.
The digit which flickers shifts as
follows every timethekey is
pressed.
②
Press thekey to display the
proportional band (P) parameter
symbol( ) on the process-value
(PV)displayunit.
①
Pressing thekeycontinuously
for 5 sec. Set the controller to
the parameter setting mode
(other than SV). Thus, the
parameter symbol is shown on
the process-valus (PV) display
unit. The last digit also flickers.
The digit which is flickering is
settable.